Baltospot
LLX200-PA
- High voltage range5 to 200 kV
- Tube current range0,5 to 12 mA
- Weight18,1 kg
Completing its range of very lightweight and powerful portable X-ray generators, Balteau NDT is adding the panoramic version of its well known LLX Series.
Air cooled and actively powerful with the smallest carbon footprint of its generation, LLX200-PA will satisfy your most complex applications and expectations.
Used in Aerospace business mostly, this compact unit can also be used in piping industry, Oil & Gas, tank, etc.
The innovative cradle will help you to not only transport this unit easily but also to adopt any position as required by your daily jobs.
LLX is controlled by a full digital control unit (DC1) using the energy saving concept of the BALTOSPOT series and our well known Hand-X® wireless remote control that is also available for your best safety.
Specifications | Units | LLX200-PA-0 |
---|---|---|
High voltage range | kV | 5 - 200 |
Tube current range | mA | 0,5 - 12 |
Maximum anode power dissipation | Watt | 600 |
Beam angle | ° | 360 x 40 |
Focal spot size (EN12543) | mm | 0,4 x 4 |
Steel penetration at max (*) | mm | 35 |
Protection | IP65 | |
Temperature switch | °C | 70° |
Inherent fi ltration | mm | 0,4 Fe/Ni/Co |
Anode cooling type | Air | |
Duty cycle | % | 100 |
Mains | V | 180 - 260 |
Weight (without rings) | Kg | 18 |
Tubehead | Metal-Ceramic | |
Control unit | DC1 or Hand-XD |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The Ceram Series is a reference in the X-Ray industry for reliability, high performances and robustness.
The Ceram 35P is the panoramic brand new portable generators designed by Balteau NDT and is offering no less than 300kV, 5mA and 100% duty cycle for an incredible image contrast even at full power.
This unit will surely become a reference on the market as it can be classified as a high power portable unit and can be operated with our classic CF2000 control unit but also with our well known Hand-X Wireless Remote Control.
Gas insulation and right components selection have succeeded in producing one of the lightest 300kV panoramic unit.. The unit is extremely versatile and is confirming our reputation of builders for machines that are really made for fi eld.
Specifications | Units | CERAM35P |
---|---|---|
High voltage range | kV | 100 - 300 |
Tube current range | mA | 0,5 - 5 |
Maximum anode power dissipation | Watt | 1500 |
Beam angle | 360 ° x 40° | |
Focal spot size (IEC336) | mm | Ø 4 x 1 |
Steel penetration at max (*) | mm | 49 |
Max recommended temp. | °C | 50° |
Temperature switch | °C | 70° |
Inherent filtration | mm | 1 Nickel/Fe |
Anode cooling type | Air | |
Duty cycle | % | 100 |
Mains | V | 180 - 260 |
Weight (without rings) | Kg | 30 |
Tubehead | Ceramic | |
Control unit | CF2000 or Hand-X |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The GFC165 is a panoramic portable unit derived from our well known Crawler series but designed to be operated on field without mechanical carriage.
It will easily surpass the poor contrast of Isotopes and will be a very interesting replacement in lower thickness ranges where Isotopes are generally not allowed.
In combination with a GFD (Directional) or a CERAM, the GFC165 is the ideal machine for field applications where the unit needs to be frequently moved or inserted in tiny spaces. Guard rings can be removed and a cradle can be used to perform difficult inspections.
This unit has to be combined to one of the two available type of control units (CF2000 or Hand X), with very lightweight new generation of cables..
High frequency
Specifications | Units | GFC165 |
---|---|---|
High voltage range | kV | 50 - 160 |
Tube current range | mA | 1 - 5 |
Maximum anode power dissipation | Watt | 800 |
Beam angle | 360° x 40° | |
Focal spot size (IEC336) | mm | Ø4 x 0.9 |
Steel penetration at max (*) | mm | 14 |
Max recommended temp. | °C | 50° |
Temperature switch | °C | 70° |
Inherent filtration | mm (Al) | 7 |
Anode cooling type | Air | |
Duty cycle | % | 100** |
Mains | V | 180 - 260 |
Weight (without rings) | Kg | 12,3 |
Tubehead | Glass | |
Control unit | CF2000 or Hand-X |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
**At a temperature of 30°C reduced mA.
The GFC205 is a panoramic portable unit derived from our well known Crawler series but designed to be operated on field without mechanical carriage. This unit has then naturally inherited the reliability of the crawler technology of Balteau NDT.
The GFC205 can deliver up to 200 kV and 5 mA and can be classified in the range of middle power units available at Balteau NDT.
It will easily surpass the poor contrast of Isotopes and will be a very interesting replacement in medium thickness ranges where Isotopes are generally not performing well.
In combination with a GFD (Directional) or a CERAM, the GFC205 will allow you to perform all kind of exposures with a limited number of units.
Specifications | Units | GFC205 |
---|---|---|
High voltage range | kV | 70 - 200 |
Tube current range | mA | 1,5 - 5 |
Maximum anode power dissipation | Watt | 1000 |
Beam angle | 360° x 40° | |
Focal spot size (IEC336) | mm | Ø5 x 1,2 |
Steel penetration at max (*) | mm | 29 |
Max recommended temp. | °C | 50° |
Temperature switch | °C | 70° |
Inherent filtration | mm (Al) | 9,1 |
Anode cooling type | Air | |
Duty cycle | % | 100** |
Mains | V | 180 - 260 |
Weight (without rings) | Kg | 25,5 |
Tubehead | Glass | |
Control unit | CF2000 or Hand-X |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
**At a temperature of 30°C reduced mA
The GFC305 is a panoramic portable unit derived from our well known Crawler series but designed to be operated on field without mechanical carriage. This unit has then naturally inherited the reliability of the crawler technology of Balteau NDT.
The GFC305 can deliver up to 300 kV and 5 mA and can be classified in the range of high power units available at Balteau NDT.
It will easily surpass the poor contrast of Isotopes and will be a very interesting replacement in medium thickness ranges where Isotopes are generally not performing well.
In combination with a GFD (Directional) or a CERAM, the GFC305 will allow you to perform all kind of exposures with a limited number of units.
Specifications | Units | GFC305 |
---|---|---|
High voltage range | kV | 140 - 300 |
Tube current range | mA | 1 - 5 |
Maximum anode power dissipation | Watt | 1500 |
Beam angle | 360° x 40° | |
Focal spot size (IEC336) | mm | Ø5 x 1,3 |
Steel penetration at max (*) | mm | 49 |
Max recommended temp. | °C | 50° |
Temperature switch | °C | 70° |
Inherent filtration | mm | 6 Al + 1,2 Cu |
Anode cooling type | Air | |
Duty cycle | % | 100** |
Mains | V | 180 - 260 |
Weight (without rings) | Kg | 35 |
Tubehead | Glass | |
Control unit | CF2000 or Hand-X |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
**At a temperature of 30°C reduced mA.
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry. Any DC voltages within the range of 72 to 130v can be selected and applied to the generator. An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarantees image quality consistency all along the exposure time. This specific process, is also improving the operating possibilities of the battery pack. Indeed much more exposures can be taken. This process improves the battery lifetime thanks to a better management of discharge cycles.
Specifications | Units | GFC160C |
---|---|---|
High voltage range | kV | 112 - 160 |
Approx. tube output | mA | 3 |
Beam angle | ° | 360 x 40 |
Focal spot size (IEC336) | mm | 4 x 0,9 |
Max. current | A | 4,5 |
Steel penetration at max (*) | mm | 12,5 |
Working temperature | °C | -10 to 40 |
Inherent fi ltration | mm | 7 Al |
Anode cooling type | Air | |
Duty cycle | % | 50% at 35°C |
Insulation | SF6 gas | |
Mains | V | 72 - 130 |
Weight | Kg | 11 |
Tubehead | Glass | |
Control unit | CF3 |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry. Any DC voltages within the range of 72 to 130v can be selected and applied to the generator. An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarantees image quality consistency all along the exposure time. This specific process, is also improving not only the operating possibilities of the battery pack, thus much more exposures can be taken before the batteries are discharged, but also it improves the battery lifetime by a better management of discharge cycles.
Specifications | Units | GFC200C |
---|---|---|
High voltage range | kV | 140 - 200 |
Approx. tube output | mA | 3 |
Beam angle | ° | 360 x 45 |
Focal spot size (IEC336) | mm | 4 x 1,2 |
Max. current | A | 9 |
Steel penetration at max (*) | mm | 24 |
Working temperature | °C | -10 to 40 |
Inherent filtration | mm | 9 Al |
Anode cooling type | Air | |
Duty cycle | % | 50% at 35°C |
Insulation | SF6 gas | |
Mains | V | 72 - 130 |
Weight | Kg | 20 |
Tubehead | Glass | |
Control unit | CF3 |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry. Any DC voltages within the range of 72 to 130 V can be selected and applied to the generator. An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarentees image quality consistency all along the exposure time. This specific process is also improving not only tje operating possibilities of the battery pack, thus much more exposures can be taken before the batteries are discharged, but also it improves the battery lifetime by a better management of discharge cycles.
Specifications | Units | GFC300C |
---|---|---|
High voltage range | kV | 150 - 300 |
Approx. tube output | mA | 3 |
Beam angle | ° | 360 x 45 |
Focal spot size (IEC336) | mm | 4 x 1,3 |
Max. current | A | 12 |
Steel penetration at max (*) | mm | 44 |
Working temperature | °C | -10 to 40 |
Inherent filtration | mm | 9 Al |
Anode cooling type | Air | |
Duty cycle | % | 50% at 35°C |
Insulation | SF6 gas | |
Mains | V | 72 - 130 |
Weight | Kg | 23,5 |
Tubehead | Glass | |
Control unit | CF3 |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry.
An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarantees image quality consistency all along the exposure time.
This specific process, is also improving the operating possibilities of the battery pack. Indeed much more exposures can be taken. This process improves the battery lifetime thanks to a better management of discharge cycles.
Specifications | Units | GCP180C |
---|---|---|
High voltage range | kV | 90 - 180 |
Approx. tube output | mA | 2,4 |
Beam angle | ° | 360 x 45 |
Focal spot size (IEC336) | mm | 5 x 0,6 |
Max. current | A | 10 |
Steel penetration at max (*) | mm | 26 |
Working temperature | °C | -40 to 70 |
Inherent fi ltration | mm | 3 Al + 2 glass |
Anode cooling type | Air | |
Duty cycle | % | 50 |
Insulation | Oil | |
Mains DC supply | V | 43 - 60 |
Weight | Kg | 16,7 |
Tubehead | Glass |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=1min.